1. Dairy Industry Use Glycol Chiller For Cooling Jacket:
Water cooled screw glycol chiller
Cooling capacity: 15TR~70TR
Outlet Temperature range: -5 degree C~ +35 degree C
Power supply: 3Phase-380V/415V/440V/460V/480V-50HZ/60HZ
2. Brewery Use Glycol Chiller Low Temperature Ice Rink
Glycol chiller type: Air cooled scroll glycol chiller
Cooling capacity: 1TR~40TR
Outlet Temperature range: -5 degree C~ +35 degree C
Power supply: 3Phase-380V/415V/440V/460V/480V-50HZ/60HZ
Dairy processing factory, Milk making factory, Beverage processing ling, Brewery , Fermentation and etc.
Supply chilling water
Product | Screw Glycol Chiller Low Temperature Ice Rink | |||
Model | MG-80WL | |||
Power supply | 3PH-380V-50HZ | |||
Chilled water flow(m3/h) | 35.3 | |||
Total power consumption (kW) | 95.3 | |||
Cooling capacity | KW | 165.6 | ||
kCal/hr | 142420 | |||
Compressor | Type | Advanced semi-hermetic screw | ||
Quantity | 1 | |||
Start method | Y-delta | |||
Energy control | 0-25%-50%-75%-100%( start @ 25%) | |||
Condenser | Type | Shell and tube | ||
Inlet/Outlet pipe dimension | PT4" | |||
Cooling water flow(m3/h) | 55 | |||
Quantity | 1 | |||
Refrigerant | Type | R22 | ||
Filling quantity (kg) | 48 | |||
Expansion valve | Type | Thermostatic expansion valve | ||
Evaporator | Type | Shell and tube | ||
Quantity | 1 | |||
Inlet/Outlet pipe dimension | PT4" | |||
Safety protection | Compressor over temperature,over current,high and low pressure,Phase sequence,phase-missing | |||
Machine Dimension | L(mm) | 2800 | ||
W(mm) | 850 | |||
H(mm) | 1700 | |||
Net Weight | kg | 1680 |
1. Our compressor is adopt Hanbell from Taiwan, Bitzer from Germany or China Fusheng brand, being of high-quality built-in safe protection, with low noise, the electricity of province is durable.
2. Cooling capacity range: 62.3kw~244kw in -5 degree C outlet.
3. Stardard Input power: 3P-380V/415V/440/460V-50Hz/60HZ, Allowable fluctuate voltage: ± 10%, allowable voltage difference in phase: ± 2%.
4. The quantity of compressor can be one or two ,each compressor is independent refrigeration system. Each other run independently.when the one is working ,the other can be working or not.
5. Use PLC or microcomputer control from Germany Siemens LCD touch screen, both English and Chinese human-machine interface.
6. Wide range of variable chilled water temperature to meet the industrial requirements throughout whole year.
7.Our standard refrigerant is R22, but you can choose to use environmental refrigerant such as R407C , R134A or R507.